Moro vacuum pumps come from a long tradition of reliability, durability and versatility. Often copied, these Italian made pumps have been an industry standard for over 30 years. Moro vacuum pumps are available in a wide range of models which differ in capacity, drive system and cooling. All Moro pumps use the principle of positive displacement rotary vanes, which guarantee a high degree of vacuum, making them suitable for a wide variety of applications. Hydraulic drives are optional. Septic Services Inc. carries a full line of accessories for Moro pumps.

| 176
CFM
Natural
convection
air
cooling
Incorporated lubricating pump
Incorporated check valve
Incorporated change-over valve
Asbestos-free spark-proof vanes
|
| Free
air
capacity |
cfm |
176 |
| Air
capacity
at
15" Hg/50%
vacuum |
cfm |
149 |
| Maximum
vacuum |
Hg |
27" |
| Maximum
pressure |
psig |
21.75 |
| Power
required
at
15" of
vacuum |
hp |
5.4 |
| Power
required
at
maximum
pressure |
hp |
7.8 |
| Rotation
speed |
r.p.m. |
1100 |
| Oil
tank
capacity |
USA
gal |
0.898 |
| Oil
consumption |
USA
gal/h |
0.047 |
| Weight |
Lbs |
187 |
| Sound
pressure
at
7meters
(23
ft)
60
%
vacuum |
dBA |
|
|
|

| 230 CFM
Natural convection air cooling
Incorporated lubricating pump
Incorporated check valve
Incorporated change-over valve
Asbestos-free spark-proof vanes
|
| Free air capacity |
cfm |
230 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
194 |
| Maximum vacuum |
Hg |
27" |
| Maximum pressure |
psig |
21.75 |
| Power required at 15" of vacuum |
hp |
8.7 |
| Power required at maximum pressure |
hp |
24 |
| Rotation speed |
r.p.m. |
1100 |
| Oil tank capacity |
USA gal |
0.898 |
| Oil consumption |
USA gal/h |
0.047 |
| Weight |
Lbs |
231 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
76 |
|
|

| 247 CFM
Natural or forced convection air cooling
Incorporated lubricating pump
Incorporated check valve
Incorporated change-over valve
Asbestos-free spark-proof vanes
|
| Free air capacity |
cfm |
247 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
212 |
| Maximum vacuum |
Hg |
28" |
| Maximum pressure |
psig |
21.75 |
| Power required at 15" of vacuum |
hp |
9 |
| Power required at maximum pressure |
hp |
20 |
| Rotation speed |
r.p.m. |
1100 |
| Oil tank capacity |
USA gal |
0.898 |
| Oil consumption |
USA gal/h |
0.047 |
| Weight |
Lbs |
287 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
76 |
|
|

| 318 CFM
Natural convection air cooling
Incorporated lubricating pump
Incorporated check valve
Incorporated change-over valve
Asbestos-free spark-proof vanes
|
| Free air capacity |
cfm |
318 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
268 |
| Maximum vacuum |
Hg |
28" |
| Maximum pressure |
psig |
29 |
| Power required at 15" of vacuum |
hp |
11 |
| Power required at maximum pressure |
hp |
35 |
| Rotation speed |
r.p.m. |
1100 |
| Oil tank capacity |
USA gal |
0.898 |
| Oil consumption |
USA gal/h |
0.063 |
| Weight |
Lbs |
309 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
78 |
|
|

| 350 CFM
Natural or forced convection air cooling
Incorporated lubricating pump
Incorporated check valve
Incorporated change-over valve
Asbestos-free spark-proof vanes
|
| Free air capacity |
cfm |
350 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
270 |
| Maximum vacuum |
Hg |
28" |
| Maximum pressure |
psig |
29 |
| Power required at 15" of vacuum |
hp |
11 |
| Power required at maximum pressure |
hp |
35 |
| Rotation speed |
r.p.m. |
1100 |
| Oil tank capacity |
USA gal |
1.2 |
| Oil consumption |
USA gal/h |
0.0063 |
| Weight |
Lbs |
401 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
78 |
|
|

| 460 CFM
Natural or forced convection air cooling
Incorporated lubricating pump
Incorporated check valve
Incorporated change-over valve
Asbestos-free spark-proof vanes
|
| Free air capacity |
cfm |
460 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
388 |
| Maximum vacuum |
Hg |
28" |
| Maximum pressure |
psig |
14.5 |
| Power required at 15" of vacuum |
hp |
18.8 |
| Power required at maximum pressure |
hp |
38 |
| Rotation speed |
r.p.m. |
1100 |
| Oil tank capacity |
USA gal |
0.924 |
| Oil consumption |
USA gal/h |
0.063 |
| Weight |
Lbs |
441 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
80 |
|
|

| 460 CFM
Natural or forced convection air cooling
Incorporated lubricating pump
Incorporated check valve
Asbestos-free spark-proof vanes
Standard with Final Filter
|
| Free air capacity |
cfm |
460 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
388 |
| Maximum vacuum |
Hg |
28" |
| Maximum pressure |
psig |
29 |
| Power required at 15" of vacuum |
hp |
17 |
| Power required at maximum pressure |
hp |
42 |
| Rotation speed |
r.p.m. |
1500 |
| Oil tank capacity |
USA gal |
1.32 |
| Oil consumption |
USA gal/h |
0.0211 |
| Weight |
Lbs |
480 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
77 |
|
|

| 547 CFM
Mixed air-liquid cooling system with forced circulation through incorporated water pump
Incorporated lubricating pump
Incorporated check valve
Incorporated change-over valve
Asbestos-free spark-proof vanes
|
| Free air capacity |
cfm |
547 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
487 |
| Maximum vacuum |
Hg |
28,3" |
| Maximum pressure |
psig |
14.5 |
| Power required at 15" of vacuum |
hp |
25.8 |
| Power required at maximum pressure |
hp |
46 |
| Rotation speed |
r.p.m. |
1000 |
| Oil tank capacity |
USA gal |
1.45 |
| Oil consumption |
USA gal/h |
0.063 |
| Weight |
Lbs |
970 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
73 |
|
|

| 677 CFM
Mixed air-liquid cooling system with forced circulation through incorporated water pump
Incorporated lubricating pump
Incorporated check valve
Incorporated change-over valve
Asbestos-free spark-proof vanes
|
| Free air capacity |
cfm |
677 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
635 |
| Maximum vacuum |
Hg |
28 |
| Maximum pressure |
psig |
14.5 |
| Power required at 15" of vacuum |
hp |
43.5 |
| Power required at maximum pressure |
hp |
61 |
| Rotation speed |
r.p.m. |
900/1250 |
| Oil tank capacity |
USA gal |
1.45 |
| Oil consumption |
USA gal/h |
0.063 |
| Weight |
Lbs |
970 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
74 |
|
|

| 824
CFM
Full
liquid
cooling
system
with
forced
circulation
through
outside
water
pump
Incorporated lubricating
pump
Asbestos-free spark-proof
vanes
Recommended for heavy industrial
application
|
| Free
air
capacity |
cfm |
824 |
| Air
capacity
at
15" Hg/50%
vacuum |
cfm |
782 |
| Nominal
vacuum |
Hg |
24" |
| Maximum
pressure |
psig |
29 |
| Power
required
at
15" of
vacuum |
hp |
50 |
| Power
required
at
maximum
pressure |
hp |
102 |
| Rotation
speed |
r.p.m. |
1500 |
| Oil
tank
capacity |
USA
gal |
2.64 |
| Oil
consumption |
USA
gal/h |
0.08 |
| Weight |
Lbs |
727 |
| Sound
pressure
at
7meters
(23
ft)
60
%
vacuum |
dBA |
74 |
|

|

| 830 CFM
Full liquid cooling system with forced circulation through outside water pump
Incorporated lubricating pump
Incorporated check valve
Incorporated change-over valve
Asbestos-free spark-proof vanes
Recommended for heavy industrial application
|
| Free air capacity |
cfm |
830 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
706 |
| Maximum vacuum |
Hg |
28.8" |
| Maximum pressure |
psig |
14.5 |
| Power required at 15" of vacuum |
hp |
43.5 |
| Power required at maximum pressure |
hp |
77.5 |
| Rotation speed |
r.p.m. |
1250 |
| Oil tank capacity |
USA gal |
1.45 |
| Oil consumption |
USA gal/h |
0.063 |
| Weight |
Lbs |
1213 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
78 |
|
|

| 1254 CFM
Full liquid cooling system with forced circulation through outside water pump
Incorporated lubricating pump
Change-over valve and check valve kit available
Asbestos-free spark-proof vanes
Recommended for heavy industrial application
|
| Free air capacity |
cfm |
1254 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
1130 |
| Maximum vacuum |
Hg |
28,8" |
| Maximum pressure |
psig |
14.5 |
| Power required at 15" of vacuum |
hp |
54.3 |
| Power required at maximum pressure |
hp |
98 |
| Rotation speed |
r.p.m. |
1000 |
| Oil tank capacity |
USA gal |
2.9 |
| Oil consumption |
USA gal/h |
0,081 |
| Weight |
Lbs |
1323 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
77 |
|
|

| 1642 CFM
Full liquid cooling system with forced circulation through outside water pump
Incorporated lubricating pump
Change-over valve and check valve kit available
Asbestos-free spark-proof vanes
Recommended for heavy industrial application
|
| Free air capacity |
cfm |
1642 |
| Air capacity at 15" Hg/50% vacuum |
cfm |
1419 |
| Maximum vacuum |
Hg |
28.8" |
| Maximum pressure |
psig |
14.5 |
| Power required at 15" of vacuum |
hp |
64.3 |
| Power required at maximum pressure |
hp |
118 |
| Rotation speed |
r.p.m. |
1000 |
| Oil tank capacity |
USA gal |
2,9 |
| Oil consumption |
USA gal/h |
0.081 |
| Weight |
Lbs |
1587 |
| Sound pressure at 7meters (23 ft) 60 % vacuum |
dBA |
78 |
|
|